Medtronic Bio-Console 560 Extracorporeal Blood Pumping Console (2021-03-05)

· Published by Health Canada · Official notice

Details

Alert type: Health product recall
Category: Health products - Medical devices - Cardiovascular
Product: Medtronic Bio-Console 560 Extracorporeal Blood Pumping Console (2021-03-05)
Issue: Medical devices - Manufacturing defect
What to do: Contact the manufacturer if you require additional information.
Audience: General public, Health professionals, Hospitals
Recall class: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Affected ProductsLot or Serial NumberModel or Catalog number
Medtronic Bio-Console 560 Extracorporeal Blood Pumping Console560B100380560
Medtronic Bio-Console 560 Extracorporeal Blood Pumping Console560B102873560BCS1
Medtronic Bio-Console 560 Extracorporeal Blood Pumping Console560B102874560BCS1

Issue

Revision D of recall: As a result of eight (8) customer complaints since revision A of this recall, a malfunction with the system controller module used in the Bio-Console 560 was identified. The malfunction is a result of the DC-DC converter and D88 diode failure because of a transient voltage spike in system controller module. This transient voltage spike has the potential to cause dielectric breakdown of the DC-DC converter front-end circuitry resulting in catastrophic failure/excessive current. Through 03-Jan-2022, this issue has resulted in eight (8) complaint occurrences (prior to use) where the instrument or user interface (UI) was not working (blank UI screen), error code 41 and/or smoking/smoking smell prior to use when the device was powered on. No adverse patient effects occurred as a result of these occurrences. Medtronic began using the affected PN in February 2021 to manufacture, service and implement part replacement per Technical Service Update (TSU) MOD0204. All Bio-Console 560 instruments manufactured (January & February 2021) with or had a system controller module installed with the affected system controller are affected by this issue. Additionally, system controller modules that are available for installation by the field service technicians for revision A of this recall are affected.

Recall start date: 2022-01-18