Health Products

Minimed

· Published by Health Canada · Official notice

Details

Alert type: Health product recall
Category: Health products - Medical devices - General hospital and personal use
Product: Minimed
Issue: Medical devices - Inaccurate test or measurement results
What to do: Contact the manufacturer if you require additional information.
Audience: General public, Health professionals, Hospitals
Recall class: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Affected productsLot or Serial NumberModel or catalog number
Minimed 770gMore than 10 numbers, contact manufacturer.MMT-1881, MMT-1891CN
Minimed 630gMore than 10 numbers, contact manufacturer.MMT-1714K, MMT-1714KRP, MMT-1714
Minimed 670gMore than 10 numbers, contact manufacturer.MMT-1782K, MMT-1782, MMT-1782KRP, MMT-1782CRP

Issue

In April 2021, while finalizing the review of complaint case-2020-00909902 related to a Minimed 630g insulin pump user who was hospitalized with hyperglycemia and DKA (diabetic ketoacidosis) on 07-dec-2020, Medtronic medical safety personnel noticed that the basal rates on the pump were still set to 0.0 units (factory default), while all other programmed settings were as expected. CAPA PR531329 was initiated to understand the cause of the issue. According to the investigation performed in CAPA PR531329, the team identified the following three (3) reasons why basal insulin may not be programmed on the pump when it is recommended by users' hcp or intended/desired: Primary root cause (or probable cause) 1. General unawareness that user settings must be manually entered prior to use of the pump. Contributing causes / contributing factors 1. 24hr technical support was unaware that the one (1) user failed to press "save" after reviewing the new basal profile. 2. The design of the user interface (UI) of the NGP pump was not intuitive to users that receive the pumps. The CAPA investigation identified that the majority of users with no basal setting (when intended) are the users who received a replacement pump or a pump upgrade. The observed 7-year cumulative rate of occurrence of this issue, i.e., P1, is approximately 0.02% for all pumps shipped and 0.03% for replacement/ upgrade pumps shipped.

Recall start date: Jan 27, 2022