Health Products

Palindrome/Mahurkar Chronic Catheter

· Published by Health Canada · Official notice

Details

Alert type: Health product recall
Category: Health products - Medical devices - General hospital and personal use
Product: Palindrome/Mahurkar Chronic Catheter
Issue: Medical devices - Performance
What to do: Contact the manufacturer if you require additional information.
Audience: Healthcare
Recall class: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberAffected productsModel or catalog number
More than 10 numbers, contact manufacturer.Palindrome Precision Chronic Catheter8888145060
8888145059
8888145061
8888145058
More than 10 numbers, contact manufacturer.Palindrome Precision H Chronic Catheter8888145046
8888145043
8888145045
8888145069
8888145044
More than 10 numbers, contact manufacturer.Palindrome Precision Hsi Chronic Catheter8888133509P
8888119369P
8888145049P
8888145048P
8888145057P
More than 10 numbers, contact manufacturer.Palindrome Precision Si Chronic Catheter8888145017
8888145039
8888145064
8888145063
8888145018
8888145041
8888145014
8888145016
8888145040
8888145042
8888145015
8888145062
More than 10 numbers, contact manufacturer.Palindrome Precision Hsi Chronic Catheter8888133509
8888119369
More than 10 numbers, contact manufacturer.Palindrome Precision H Chronic Catheter8888128455
8888119365
8888123405
More than 10 numbers, contact manufacturer.Mahurkar Chronic Carbothane Catheters8888145003
8888145002
8888145004
8888145001
More than 10 numbers, contact manufacturer.Mahurkar Chronic Carbothane Catheters8888145028
8888145027
More than 10 numbers, contact manufacturer.Mahurkar Chronic Carbothane Catheters8888119385
8888133535
8888123435
8888128485
More than 10 numbers, contact manufacturer.Mahurkar Chronic Carbothane Catheters8888145251
8888145252
8888145254
8888145253
More than 10 numbers, contact manufacturer.Palindrome Precision Chronic Catheter8888133504P
8888123400P
8888128450P
8888119360P
8888119364P
8888128454P
8888123404P
More than 10 numbers, contact manufacturer.Mahurkar Chronic Carbothane Catheters8888119362
More than 10 numbers, contact manufacturer.Palindrome Precision Chronic Catheter8888145014P
8888145039P
8888145042P
8888145017P
8888145015P
8888145018P
8888145016P
8888145040P
8888145041P
8888146044P
More than 10 numbers, contact manufacturer.Palindrome Precision Chronic Catheter8888123400
8888123410
8888128450
8888119360
8888119364
8888119370
8888128454
8888133504
8888123404
8888128460
More than 10 numbers, contact manufacturer.Palindrome Precision Chronic Catheter8888119365P
8888145046P
8888145043P
8888145045P
8888145044P
8888128455P
8888123405P
8888145069P
More than 10 numbers, contact manufacturer.Palindrome Precision Si Chronic Catheter8888145063P
8888145064P
8888145062P
8888119368P
8888123408P
More than 10 numbers, contact manufacturer.Palindrome Precision Hsi Chronic Catheter8888145049
8888145057
8888145048
More than 10 numbers, contact manufacturer.Palindrome Precision Si Chronic Catheter8888119368
8888123408
More than 10 numbers, contact manufacturer.Palindrome Precision Chronic Catheter8888128460P
8888123410P
8888119370P
8888145058P
8888145061P
8888145059P

Issue

Medtronic has identified a potential leaking condition within the hub of specific chronic hemodialysis catheters. Flushing one extension tube may result in unanticipated fluid return through the adjacent extension tube (in addition to the anticipated flow of fluid through the distal tip of the catheter). The condition is the result of an inter-lumen void formed in the hub component of the catheter during the manufacturing process. during use, this observed condition could translate to cross-communication of the blood circuit.

Recall start date: June 9, 2022

Get told about the next health product recall.
Get health product recall alerts

CA$3.99/mo · cancel anytime