Health Products

Magnets in certain Philips Respironics sleep therapy masks may cause serious injury to some individuals

· Published by Health Canada · Official notice

Details

Alert type: Public advisory
Category: Health products - Medical devices
Product: Philips Respironics sleep therapy masks with magnets in the headgear clips or straps (Amara View Full Face Mask; DreamWisp Nasal Mask; DreamWear Full Face Mask; Wisp and Wisp Youth Nasal Mask; and Therapy Mask 3100 NC/SP)
Issue: Health products - New safety information
What to do: STOP USING the affected mask if you or any of your household members, caregivers or bed partners have any of the implanted devices listed below in the “What you should do” section that may be affected by magnets. Obtain another mask that has no magnets. Keep implanted metallic medical devices or objects NOT listed below that may be affected by magnetic fields at least 6 inches—or approximately 15 cm—away from the magnet, and either continue using or seek a replacement mask that has no magnets.
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Images

Products

ProductPhoto
Therapy Mask 3100 NC/SP
(magnets are circled in black)
DreamWear Full Face Mask
(magnets are circled in black)
Wisp and Wisp Youth Nasal Mask
(magnets are circled in black)
Amara View Full Face Mask
(magnets are circled in black)
DreamWisp Nasal Mask
(magnets are circled in black)

Issue

Certain Philips Respironics sleep therapy masks used with Continuous Positive Airway Pressure (CPAP) or Bi-Level Positive Airway Pressure (BiPAP) machines have magnets in their headgear clips or straps. These magnets could cause safety concerns for people who may be vulnerable to magnetic fields. The sleep therapy mask magnets are used to attach the headgear clips or straps to the mask. Their magnetic field can potentially affect their function or displace some metallic medical devices or objects (e.g., pacemakers, metallic stents, metal in the eye) which may result in serious injury. Philips Respironics is adding a contraindication and is updating product warnings and instructions for use (IFU) to help prevent injury to patients and those close to them, who may be vulnerable to magnetic fields. Philips Respironics has received international reports of potential magnet interference with patient medical devices. These reports include: pacemaker alarms and interference, arrhythmia (irregular heart beat), pacemaker failure leading to replacement, need for shunt adjustment, resetting of automatic implantable cardioverter defibrillator, seizures, defibrillator shutting off periodically and cognitive issues. To date, no incidents have been reported in Canada. Health Canada is advising patients that the affected masks should not be used by patients if they or a person in close proximity to them including, household members, caregivers, or bed partners have any of the implanted metallic medical devices or objects listed below inside their bodies. For patients who have other metallic medical devices or objects inside their bodies that are not included on the list below but that may be affected by magnets, the manufacturer warns that the affected masks should be kept at least 6 inches (approximately 15 cm) away from the device/object. Please note this issue is not related to the recall of Philips Respironics CPAP and BiLevel PAP machines and mechanical ventilators due to issues involving the sound abatement foam, which Health Canada first communicated about in June 2021 and provided an update to in July 2022.