Health ProductsType I recall

Philips Allura XPER, Allura Centron and Azurion Systems

· Published by Health Canada · Official notice

Details

Alert type: Health product recall
Category: Health products - Medical devices - Radiology
Product: Philips Allura XPER, Allura Centron and Azurion Systems
Issue: Medical devices - Performance
What to do: Contact the manufacturer if you require additional information.
Audience: Healthcare
Recall class: Type I
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberAffected productsModel or catalog number
Not applicable.Allura XPER FD20/20 (Product Of Alluraclarity Family)722038
Not applicable.Azurion 7 M20722 224
722 079
Not applicable.Allura XPER FD20/15722058
Not applicable.Allura XPER FD20 (Product Of Alluraclarity Family)722028
Not applicable.Allura XPER FD20/10 (Product Of Alluraclarity Family)722029
Not applicable.Allura XPER FD20/20 OR Table (Product Of Alluraclarity Family)722039
Not applicable.Azurion 7 B20722 068
Not applicable.Allura XPER FD10/10 (Product Of Alluraclarity Family)722027
Not applicable.Allura XPER FD10 (Product Of Alluraclarity Family)722026
Not applicable.Azurion 7 B12722067
Not applicable.Azurion 7 M12722 223
722 078
Not applicable.Azurion 5 M12722 227
Not applicable.Allura XPER FD20 Or Table (Product Of Alluraclarity Family)722023
Not applicable.Azurion 5 M20722228
Not applicable.Allura XPER FD10001443

Issue

Philips has become aware of issues with three (3) components in certain PCs used with the Philips Allura XPER, Allura Centron and/or Azurion systems that may result in a loss of system functionality. Three (3) components of the PCs may not perform as intended due to manufacturing issues. The PCs within your system may have one (or more) of the impacted components. 1. Dimms (dual in-line memory modules): system may stop functioning and imaging may not be possible. 2. Disk bay: System may stop functioning and imaging may not be possible (eg. unresponsive, frozen images). 3. Framegrabber card: Flexvision monitor may show no viewports, or one or more viewports may show no image, a distorted image, or a frozen image. also, switching between viewports on the flexvision monitor may be possible.

Recall start date: January 5, 2024