Health Products

CADD-Solis™ Ambulatory Infusion Pump

· Published by Health Canada · Official notice

Details

Alert type: Health product recall
Category: Health products - Medical devices - General hospital and personal use
Product: CADD-Solis™ Ambulatory Infusion Pump
Issue: Medical devices - Performance
What to do: Contact the manufacturer if you require additional information.
Audience: Healthcare
Recall class: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Affected productsLot or serial numberModel or catalog number
CADD-Solis™ Ambulatory Infusion PumpMore than 10 numbers, contact manufacturer.21-2101-0200-02
21-2111-0403-78
21-2112-0400-51
21-2112-0401-51
21-2112-0403-78
21-2102-51
21-2111-0100-51
21-2111-0300-00
21-2111-0400-51
21-2111-0401-51
21-2111-0403-51
21-2112-0200-02
21-2112-0300-50
21-2112-0403-02
21-2112-0403-51
21-2111-0300-02
21-2112-0300-02
21-2111-0300-50
21-2112-0100-51
21-2111-0403-02
21-2101-51
21-2111-0200-02
CADD-Solis VIP™ Ambulatory Infusion PumpMore than 10 numbers, contact manufacturer.21-2120-0100-95
21-2120-0103-02
21-2120-0100-50
21-2120-0102-92
21-2120-0103-51
21-2120-0102-51
21-2120-0100-02
21-2120-0102 -02
21-2120-0102-78
21-2120-0103-78
21-2120-0100-51

Issue

Under certain conditions, a CADD-Solis™ pump may trigger an erroneous (false) upstream occlusion (USO) alarm. The erroneous USO alarm may occur when there is a delay of more than one hour between the first prime or infusion of a new CADD administration set and the next prime or infusion of the same CADD administration set. The USO alarm is a high priority alarm that will interrupt an ongoing infusion or delay initiation of an infusion. The pump cannot resume or start an infusion until the alarm is cleared. A USO alarm may potentially occur if all these conditions are met: using a CADD administration set (i.e. not a medication cassette reservoir), and enabling the upstream occlusion alarm, and not programming keep vein open (KVO) or continuous rate, and priming or infusing shortly after attaching the administration set and the next infusion does not occur for approximately one hour or longer. This issue will not occur when using a medication cassette reservoir, if the USO alarm is disabled, if the KVO setting is programmed, or if a continuous rate setting is programmed. Recall start date: April 8, 2025