Allura and Azurion Systems

· Published by Health Canada · Official notice

Details

Alert type: Health product recall
Category: Health products - Medical devices - Radiology
Product: Allura and Azurion Systems
Issue: Medical devices - Performance
What to do: Contact the manufacturer if you require additional information.
Audience: Healthcare
Recall class: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Affected productsLot or serial numberModel or catalog number
Allura Xper FD20878722028
Allura Xper FD20231722028
Allura Xper FD201572722028
Allura Xper FD201039722028
Allura Xper FD20758722028
Allura Xper FD20663722028
Allura Xper FD20942722028
Allura Xper FD20763722028
Allura Xper FD20 OR Table128722035
Allura Xper FD20 OR Table111722035
Azurion 7 B12128722 067
Azurion 7 B12151722 067
Azurion 7 B20265722 068
Azurion 7 B20275722 068
Allura Xper FD10More than 10 numbers, contact manufacturer.722026
Azurion 7 M12More than 10 numbers, contact manufacturer.722 223
Azurion 7 M12More than 10 numbers, contact manufacturer.722 078
Azurion 7 M20More than 10 numbers, contact manufacturer.722 224
Azurion 7 M20More than 10 numbers, contact manufacturer.722 079

Issue

The 1 Phase UPS is an optional component that can be installed in Allura and Azurion systems to support a controlled shutdown of the PCs (the computers that control the system) in the event of a mains power failure. The 1 Phase UPS provides temporary power to the PCs, allowing the system to save the data of the last acquired run before the PCs shut down. Philips has become aware of a potential safety issue with Philips Azurion and Allura systems configured with a 1 Phase uninterruptible power supply (UPS). Philips has identified that some internal components of the 1 Phase UPS may fail. When this occurs, there will be a complete loss of power to the system, causing the system to shut down and/or not start up. The 1 Phase UPS system may fail without warning and prior to any mains power failure. If the system does not start up or the system shuts down, there is a potential risk of delay or termination of the procedure. The potential delay in treatment and/or termination of the procedure may result in serious adverse health outcomes, including the possibility of death, especially when the system is used with critical patients, particularly those undergoing complex and/or urgent interventions for potentially life-threatening conditions (e.g., acute ischemic stroke, st-segment elevation myocardial ischemia). Recall start date: July 31, 2025