· Published by Health Canada · Official notice
| Common name | Place of origin | Companies | Number sold | Product description | Hazard identified | Time period sold |
|---|---|---|---|---|---|---|
| Fluke/Tektronix Scope Meters | Manufactured in the Netherlands. |
| Approximately 22 units of the affected Fluke scope meters and 14 units of the affected Tektronix meters were sold by Fluke/Tektronix and their authorized distributors across Canada. | This recall involves the following scope meters: | An error in a release of software code (containing firmware version V10.40 in Fluke units and V1.0 in Tektronix units) may cause incorrect display readings in the 50V and lower voltage ranges. As an example, the products can report a measurement of 10.0V as 100V or 100V as 10.0V. | Software V10.40 in Fluke units were shipped from February 5, 2012 to April 6, 2012, and software V1.0 in Tektronix units were shipped December 15, 2011 to April 6, 2012. |