Advia Centaur System - Instruments

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: General Public (GP), Healthcare Professionals, Hospitals
Department: Health Canada
Hazard classification: Type III
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberCompaniesBrand nameModel or catalog number
More than 10 numbers, contact manufacturer
Manufacturer
Siemens Healthcare Diagnostics Inc.
F. Advia Centaur System - Instrument Class IV04911855, 078-A001-14
More than 10 numbers, contact manufacturer
Manufacturer
Siemens Healthcare Diagnostics Inc.
D. Advia Centaur XP System - Instrument Class III078-A010-07, 09066916
More than 10 numbers, contact manufacturer
Manufacturer
Siemens Healthcare Diagnostics Inc.
E. Advia Centaur System - Instrument Class II04911855, 078-A001-14
More than 10 Numbers, contact manufacturer
Manufacturer
Siemens Healthcare Diagnostics Inc.
B. Advia Centaur XP System - Instrument Class 2078-A010-07, 09066916
More than 10 numbers, contact manufacturer
Manufacturer
Siemens Healthcare Diagnostics Inc.
C. Advia Centaur XP System - Instrument Class IV078-A010-07, 09066916
More than 10 Numbers, contact manufacturer
Manufacturer
Siemens Healthcare Diagnostics Inc.
A. Advia Centaur System - Instrument Class 304911855, 078-A001-14

Introduction

Recalled Products
  1. Advia Centaur System - Instrument Class 3
  2. Advia Centaur XP System - Instrument Class 2
  3. Advia Centaur XP System - Instrument Class IV
  4. Advia Centaur XP System - Instrument Class III
  5. Advia Centaur System - Instrument Class II
  6. Advia Centaur System - Instrument Class IV

Reason

The wash interconnect circuit board on the Advia Centaur / Advia Centaur XP can fail due to contamination on the board during manufacturing and/or during use.  When a failure occurs, it is possible to have incorrect reporting of the wash1 sensors status. The fluid line of either sensor (S1 or S2) is reported to be empty when it is actually full, or reported to be full when it is empty.  These failures could either lead to the system not detecting an empty wash1 bottle or reservoir, or stop the system from running due to a supposedly empty wash1 reservoir.  If the sensors both fail in the "wet" state due to the board malfunction, an erroneous but believable result may be released to the physician which is falsely high or low (depending on the assay architecture - Competitive or Sandwich).