Advia Centaur System – Instruments (Monthly and Daily Cleaning Procedure)

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: General Public, Healthcare Professionals, Hospitals
Department: Health Canada
Hazard classification: Type III
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberCompaniesBrand nameModel or catalog number
N/A
Manufacturer
Siemens Healthcare Diagnostics Inc.
500 GBC Drive, Mailstop 514, PO Box 6101
Newark
19714-6101
Delaware
UNITED STATES
F. Advia Centaur System – Instrument04911855
N/A
Manufacturer
Siemens Healthcare Diagnostics Inc.
500 GBC Drive, Mailstop 514, PO Box 6101
Newark
19714-6101
Delaware
UNITED STATES
D. Advia Centaur XP System – Instrument078-A010-07
N/A
Manufacturer
Siemens Healthcare Diagnostics Inc.
500 GBC Drive, Mailstop 514, PO Box 6101
Newark
19714-6101
Delaware
UNITED STATES
E. Advia Centaur System – Instrument04911855
N/A
Manufacturer
Siemens Healthcare Diagnostics Inc.
500 GBC Drive, Mailstop 514, PO Box 6101
Newark
19714-6101
Delaware
UNITED STATES
B. Advia Centaur XP System – Instrument078-A010-07
N/A
Manufacturer
Siemens Healthcare Diagnostics Inc.
500 GBC Drive, Mailstop 514, PO Box 6101
Newark
19714-6101
Delaware
UNITED STATES
C. Advia Centaur XP System – Instrument078-A010-07
N/A
Manufacturer
Siemens Healthcare Diagnostics Inc.
500 GBC Drive, Mailstop 514, PO Box 6101
Newark
19714-6101
Delaware
UNITED STATES
A. Advia Centaur System – Instrument04911855

Introduction

Recalled products
  1. Advia Centaur System – Instrument
  2. Advia Centaur XP System – Instrument
  3. Advia Centaur XP System – Instrument
  4. Advia Centaur XP System – Instrument
  5. Advia Centaur System – Instrument
  6. Advia Centaur System – Instrument

Reason

The Monthly Cleaning Procedure (MCP) maintenance, under certain circumstances, may result in residual cleaning solution (Bleach) in the Reagent Probe 1 (RP1) fluidics and the water reservoir causing false results. Tests affected are Total Human Chorionic Gonadotropin (THCG), Progesterone and Prostate Specific Antigen (PSA). The Daily Cleaning Procedure (DCP) under certain circumstances may result in residual cleaning solution (Bleach) in the water line causing false results that use water for test processing. Test affected is Toxoplasma M (Toxo M).