Health Products

Vitros Systems (2014-04-11)

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: General Public, Healthcare Professionals, Hospitals
Department: Health Canada
Hazard classification: Type III
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberCompaniesBrand nameModel or catalog number
More than 10 numbers, contact manufacturer
Manufacturer
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
F.  Vitros 4600 Chemistry System - Hardware680 2445
More than 10 numbers, contact manufacturer
Manufacturer
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
D. Vitros 5600 Integrated System - Instrument680 2413
More than 10 numbers, contact manufacturer
Manufacturer
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
E. Vitros 5600 Integrated System680 2413
More than 10 numbers, contact manufacturer
Manufacturer
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
B. Vitros Chemistry Products 5.1 FS Chemistry System - Refurbished6801890
More than 10 numbers, contact manufacturer
Manufacturer
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
C. Vitros Chemistry Products 5.1 FS Chemistry System - Instrument6801375
More than 10 numbers, contact manufacturer
Manufacturer
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
A. Vitros Chemistry Products 5.1 FS Chemistry System - Analyzer6801375

Introduction

Recalled Products

A. Vitros Chemistry Products 5.1 FS Chemistry System - Analyzer
B. Vitros Chemistry Products 5.1 FS Chemistry System - Refurbished
C. Vitros Chemistry Products 5.1 FS Chemistry System - Instrument
D. Vitros 5600 Integrated System - Instrument
E. Vitros 5600 Integrated System
F.  Vitros 4600 Chemistry System - Hardware

Reason

OCD has issued a recall due to the potential for biased results when a multiple window (MW) code is associated with results generated by the Vitros 5600 Integrated system, Vitros 4600 Chemistry system and Vitros 5.1 Chemistry system. MW codes may be associated with results from any of the following Vitros Chemistry products using multiple point (Multipoint) rate measurements: Alt slides, ALKP slides, AST slides, CHE slides, CK slides, GGT slides, LDH slides. Multipoint rate assays measure enzyme activity via multiple readings which are used to generate a kinetic curve and calculate results. The MW algorithm assesses the validity of the kinetic curve. An MW code is generated if a single point exceeds predetermined limits, provided that all surrounding values are within acceptable limits.