Lot or serial numberBrand nameCompaniesModel or catalog number
All lots.H) Beckman Coulter AU Immunochemistry System - Lipase
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6130
All lots.I) Beckman Coulter AU Immunochemistry System - Lactate
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6193
All lots.F) Beckman Coulter AU2700 Immunochemistry System - Uric Acid
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6098
All lots.G) Beckman Coulter AU Immunochemistry System - Cholesterol
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6116
All lots.D) Beckman Coulter AU2700 Immunochemistry System - Lactate
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6193
All lots.E) Beckman Coulter AU5400 Immunochemistry System - Uric Acid
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6098
All lots.B) Beckman Coulter AU5400 Immunochemistry System - Cholesterol
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6116
All lots.K) Beckman Coulter AU2700 Immunochemistry System - Lipase
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6130
All lots.L) Beckman Coulter AU5400 Immunochemistry System - Lipase
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6130
All lots.C) Beckman Coulter AU5400 System - Lactate Assay
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6193
All lots.M) Beckman Coulter AU Immunochemistry System - Enzymatic Creatinine
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR61204
All lots.A) Beckman Coulter AU2700 Immunochemistry System - Cholesterol
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6116
All lots.J) Beckman Coulter AU Immunochemistry System - Uric Acid
Manufacturer
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea
92821
California
UNITED STATES
OSR6098

Introduction

Recalled Products
  1. Beckman Coulter AU2700 Immunochemistry System - Cholesterol
  2. Beckman Coulter AU5400 Immunochemistry System - Cholesterol
  3. Beckman Coulter AU5400 System - Lactate Assay
  4. Beckman Coulter AU2700 Immunochemistry System - Lactate
  5. Beckman Coulter AU5400 Immunochemistry System - Uric Acid
  6. Beckman Coulter AU2700 Immunochemistry System - Uric Acid
  7. Beckman Coulter AU Immunochemistry System - Cholesterol
  8. Beckman Coulter AU Immunochemistry System - Lipase
  9. Beckman Coulter AU Immunochemistry System - Lactate
  10. Beckman Coulter AU Immunochemistry System - Uric Acid
  11. Beckman Coulter AU2700 Immunochemistry System - Lipase
  12. Beckman Coulter AU5400 Immunochemistry System - Lipase
  13. Beckman Coulter AU Immunochemistry System - Enzymatic Creatinine

Reason

N-acetyl cysteine (NAC), when administered in therapeutic concentrations in excess of 500 mg/l (for the treatment of acetaminophen overdose), has been recently determined to interfere with assays for the following analytes: enzymatic creatinine OSR 6x204, cholesterol OSR 6x16, uric acid OSR 6x98, lactate OSR 6x93, and lipase OSR 6x30.

Only these assays are affected. NAC is an anti-oxidant and can interfere with assays employing Trinder Chemical Pathways, i.e. Where hydrogen peroxide (H2O2) is formed and subsequently reacted with amino antipyrine and an indicator in the presence of a peroxidase as a catalyst. NAC interference has been demonstrated to occur to varying degrees depending on the analytes and therefore not all assays employing Trinder Chemical Pathways are affected.

NAC interference may lead to falsely low results.