Vehicles

NORCOLD issued a recall on the 322323,N260, and N300 models

· Published by Transport Canada · Official notice

Details

Alert type: Recall
Category: Equipment
Department: Transport Canada
Notification type: Safety Industry
System: Other
Units affected: 127,035
Get told about the next recall on your Norcold 322.

We email or text you when Transport Canada lists a new recall for the vehicle you name. Dealer and manufacturer letters can take weeks.

Get alerts for my Norcold 322

CA$3.99/mo · cancel anytime

Products

ModelMakeModel year(s) affected
322NORCOLD1992, 1993, 1994, 1995, 1996, 1997, 1998, 1999

More recalls for these vehicles

The issue

On certain gas/electrical absorption RV and camping trailer refrigerators, the pressure tap device swivel nut may experience stress corrosion cracking. If the nut is cracked severely enough to relax the flare joint between the aluminum gas line tube and the pressure tap component, propane fuel gas has the potential to leak if the refrigerator is activated for operation in gas mode. This can present the potential for a fire to occur in the area behind the refrigerator if the leakage and accumulation is substantial enough to ignite from an adjacent burner. Correction: Swivel nut will be replaced.