Vehicles

NORCOLD issued a recall on the N621N641,N821, and N841 models

· Published by Transport Canada · Official notice

Details

Alert type: Recall
Category: Equipment
Department: Transport Canada
Notification type: Safety Industry
System: Other
Units affected: 1,598
Get told about the next recall on your 1999 Norcold N841.

We email or text you when Transport Canada lists a new recall for the vehicle you name. Dealer and manufacturer letters can take weeks.

Get alerts for my 1999 Norcold N841

CA$3.99/mo · cancel anytime

Products

ModelMakeModel year(s) affected
N841NORCOLD1999

More recalls for these vehicles

The issue

On certain 3-way refrigerators (propane AC and DC), a low cycle fatigue failure could occur in the section of the cooling unit which generates the refrigerant. This occurs due to elevated heat when the refrigerator is operated in the AC power mode. This fracture can cause the liquid solution to leak from the cooling unit and can result in the generation of very high temperatures. This can in turn cause the steel material to soften and rupture and if the pressurizing hydrogen gas is still in place when the rupture occurs, the gas may be expelled and possibly be ignited by the high temperature causing a fire. Correction: A new cooling unit will be installed.