Vitros Chemistry Systems (2015-04-07)

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: General Public, Healthcare Professionals, Hospitals
Department: Health Canada
Hazard classification: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberCompaniesBrand nameModel or catalog number
More than 10 numbers, contact manufacturer.
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
F. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #80701)6802413
More than 10 numbers, contact manufacturer.
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
G. VITROS 4600 CHEMISTRY SYSTEM (DEVICE LICENCE #85176 AND #86236)6802445
More than 10 numbers, contact manufacturer.
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
D. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361, REFURBISHED)6801375
More than 10 numbers, contact manufacturer.
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
E. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #78571)6802413
More than 10 numbers, contact manufacturer.
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
B. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236, REFURBISHED)6801375
More than 10 numbers, contact manufacturer.
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
C. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361)6801375
More than 10 numbers, contact manufacturer.
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
A. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236)6801375

Introduction

Recalled Products

A. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236)
B. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236, REFURBISHED)
C. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361)
D. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361, REFURBISHED)
E. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #78571)
F. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #80701)
G. VITROS 4600 CHEMISTRY SYSTEM (DEVICE LICENCE #85176 AND #86236)

Reason

Ortho-Clinical Diagnostics, Inc. (OCD) has confirmed instances where the Vitros system allowed urine samples for assays that required acidified pretreatment to be metered from the same sample container as assays that required no pretreatment when the sample was programmed. This has been attributed to a software anomaly. Depending upon the assay, urine samples either need to be acidified, alkalized or require no pretreatment. The anomaly occurs when manually programming urine samples or using a downloaded sample program from a laboratory information system (LIS) and the sample program contains assays requiring sample pretreatment and assays requiring no sample pretreatment. if this anomaly occurs, it is possible for Vitros 5,1, 4600 or 5600 systems to process urine samples without the proper pretreatment, potentially leading to biased patient results.