VITROS 5.1 FS CHEMISTRY SYSTEMS ( 2015-06-30)

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: General Public, Healthcare Professionals, Hospitals
Department: Health Canada
Hazard classification: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberBrand nameCompaniesModel or catalog number
>10 NUMBERS, CONTACT MFGD. VITROS 5,1 FS CHEMISTRY SYSTEM (REFURBISHED) (LICENCE #67361)
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
6801890
>10 NUMBERS, CONTACT MFGB. VITROS 5,1 FS CHEMISTRY SYSTEM (REFURBISHED) (LICENCE #66236)
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
6801890
>10 NUMBERS, CONTACT MFGC. VITROS 5,1 FS CHEMISTRY SYSTEM (LICENCE #67361)
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
6801375
>10 NUMBERS, CONTACT MFGA. VITROS 5,1 FS CHEMISTRY SYSTEM (LICENCE #66236)
Manufacturer
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
6801375

Introduction

Affected Products
  1. VITROS 5,1 FS CHEMISTRY SYSTEM (LICENCE #66236)
  2. VITROS 5,1 FS CHEMISTRY SYSTEM (REFURBISHED) (LICENCE #66236)
  3. VITROS 5,1 FS CHEMISTRY SYSTEM (LICENCE #67361)
  4. VITROS 5,1 FS CHEMISTRY SYSTEM (REFURBISHED) (LICENCE #67361)

Reason

Ortho Clinical Diagnostics (OCD) has identified a software anomaly that may occur during the installation of an Assay Data Diskette (ADD) using software versions 2.2.1 through 2.8. The anomaly is not caused by the (ADD).
OCD received two customer complaints (outside of Canada) that occurred during the installation of the (ADD). Due to a software coding error for both scenarios, all default settings were restored from the (ADD) instead of retaining the user configured parameters and the operator was not alerted by the system. If this anomaly occurs, the VITROS 5.1 FS System may process samples using the default reporting units from the (ADD) instead of the user modified parameters (i.e. SI vs conventional units). However, numerical results will be correct for the actual units reported on the VITROS System.