Unicel DxC SYNCHRON ACCESS INTEGRATED Clinical Systems (2015-07-20)

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: General Public, Healthcare Professionals, Hospitals
Department: Health Canada
Hazard classification: Type III
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberCompaniesBrand nameModel or catalog number
3048
Manufacturer
Beckman Coulter
Inc.
250 S. Kraemer Blvd.
California
UNITED STATES
F. UniCel DxC 860i SYNCHRON ACCESS INTEGRATED Clinical Systems4773
2788
Manufacturer
Beckman Coulter
Inc.
250 S. Kraemer Blvd.
California
UNITED STATES
D.UniCel DxC 880i SYNCHRON ACCESS INTEGRATED Clinical Systems 4768
4036
Manufacturer
Beckman Coulter
Inc.
250 S. Kraemer Blvd.
California
UNITED STATES
E. Unicel DxC 660i SYNCHRON ACCESS INTEGRATED Clinical Systems4771
>10 numbers, contact mfg.
Manufacturer
Beckman Coulter
Inc.
250 S. Kraemer Blvd.
California
UNITED STATES
B. UniCel DxC 800 SYNCHRON Clinical Systems4764
>10 numbers, contact mfg
Manufacturer
Beckman Coulter
Inc.
250 S. Kraemer Blvd.
California
UNITED STATES
C. UniCel DxC 600i SYNCHRON ACCESS INTEGRATED Clinical Systems4767
>10 numbers, contact mfg.
Manufacturer
Beckman Coulter
Inc.
250 S. Kraemer Blvd.
California
UNITED STATES
A. UniCel DxC 600 SYNCHRON Clinical Systems4764

Introduction

Affected Products
  1. UniCel DxC 600 SYNCHRON Clinical Systems
  2. UniCel DxC 800 SYNCHRON Clinical Systems
  3. UniCel DxC 600i SYNCHRON ACCESS INTEGRATED Clinical Systems
  4. UniCel DxC 880i SYNCHRON ACCESS INTEGRATED Clinical Systems
  5. Unicel DxC 660i SYNCHRON ACCESS INTEGRATED Clinical Systems
  6. UniCel DxC 860i SYNCHRON ACCESS INTEGRATED Clinical Systems

Reason

Beckman Coulter has identified a failure of the UniCel DxC ISE Tubing (lines 11, 25 and 26) for ISE reference reagent. The failure occurs due to the interaction between a new tubing plasticizer and the ISE reference reagent. The supplier's change in plasticizer was a result of a move to a phthalate-free tubing material based on new environmental regulations. As a result, a slow forming non-microbial white material may appear inside the tubing. Observed symptoms of the presence of the white material can include suppressed ion specific electrode (ISE) quality control and patient results, ISE calibration failures, and detached tubing lines 25 or 26 due to obstruction of flow. Current investigation suggests it is highly unlikely that incorrect results will be generated.