VITROS Integrated/ Chemistry Systems (2015-12-21)

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: General Public, Healthcare Professionals, Hospitals
Department: Health Canada
Hazard classification: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberCompaniesBrand nameModel or catalog number
More than 10 numbers, contact manufacturer
Manufacturer
Ortho Clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
H. VITROS 5600 Integrated System680 2413
More than 10 numbers, contact manufacturer
Manufacturer
Ortho Clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
I. VITROS 4600 Chemistry System680 2445
More than 10 numbers, contact manufacturer
Manufacturer
Ortho Clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
F. VITROS 350 Chemistry System - Analyzer680 2153
More than 10 numbers, contact manufacturer
Manufacturer
Ortho Clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
G. VITROS 5600 Integrated System - Instrument680 2413
More than 10 numbers, contact manufacturer
Manufacturer
Ortho Clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
D. VITROS 5,1 FS Chemistry System - Instrument680 1375
More than 10 numbers, contact manufacturer
Manufacturer
Ortho Clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
E. VITROS 350 Chemistry System - Vitros 350 Analyzer680 2153
More than 10 numbers, contact manufacturer
Manufacturer
Ortho Clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
B. VITROS 250 Chemistry System - Class 36801759
More than 10 numbers, contact manufacturer
Manufacturer
Ortho Clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
C. VITROS 5,1 FS Chemistry System - Class II680 1375
More than 10 numbers, contact manufacturer
Manufacturer
Ortho Clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
A. VITROS 250 Chemistry System6801759

Introduction

Afftected Products
  1. VITROS 250 Chemistry System
  2. VITROS 250 Chemistry System - Class 3
  3. VITROS 5,1 FS Chemistry System - Class II
  4. VITROS 5,1 FS Chemistry System - Instrument
  5. VITROS 350 Chemistry System - Vitros 350 Analyzer
  6. VITROS 350 Chemistry System - Analyzer
  7. VITROS 5600 Integrated System - Instrument
  8. VITROS 5600 Integrated System
  9. VITROS 4600 Chemistry System

Reason

Ortho-Clinical Diagnostics, inc. (ortho) initiated this urgent product correction notification due to the need to clarify operator actions following U90-382 or 6LU condition codes generated by the systems affected by this recall. U90-382 or 6LU condition codes are associated with wash errors that may occur when using VITROS chemistry products for Immuno-Rate assays (i.e. VITROS, CRBM, CRP, DGXN, and PHYT slides).  If a U90-382 or 6LU condition code (i.e., associated with a wash error) occurs, the condition code text located on the VITROS system and other user documentation indicates to dilute the sample. However, dilution may not be the appropriate action for all scenarios. 