Maquet Life Support Set and associated products (2015-12-07)

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: Healthcare Professionals, General Public, Hospitals
Department: Health Canada
Hazard classification: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberCompaniesBrand nameModel or catalog number
More than 10 numbers, contact manufacturer.
Manufacturer
Maquet Cardiopulmonary Ag
Kehler Str. 31
Rastatt
F. PERFUSION SET WITH BIOLINE COATINGBEQ-HQV 52302
More than 10 numbers, contact manufacturer.
Manufacturer
Maquet Cardiopulmonary Ag
Kehler Str. 31
Rastatt
D. CARDIOHELP HLS DISPOSABLE SETBE-HLS 5050
More than 10 numbers, contact manufacturer.
Manufacturer
Maquet Cardiopulmonary Ag
Kehler Str. 31
Rastatt
E. HLS SET ADVANCED 5.0/7.0 WITH BIOLINE COATINGBEQ-HLS 5050-CA
More than 10 numbers, contact manufacturer.
Manufacturer
Maquet Cardiopulmonary Ag
Kehler Str. 31
Rastatt
B. QUADROX-ID ADULT OXYGENATOR (WITH BIOLINE)BE-HMOD 70000
More than 10 numbers, contact manufacturer.
Manufacturer
Maquet Cardiopulmonary Ag
Kehler Str. 31
Rastatt
C. QUADROX-ID ADULT OXYGENATOR (WITH SOFTLINE)HMOD 70000-USA
More than 10 numbers, contact manufacturer.
Manufacturer
Maquet Cardiopulmonary Ag
Kehler Str. 31
Rastatt
A. PERMANENT LIFE SUPPORT SETBE-PLS 2050

Introduction

Affected products
  1. PERMANENT LIFE SUPPORT SET


  2. QUADROX-ID ADULT OXYGENATOR (WITH BIOLINE)


  3. QUADROX-ID ADULT OXYGENATOR (WITH SOFTLINE)


  4. CARDIOHELP HLS DISPOSABLE SET


  5. HLS SET ADVANCED 5.0/7.0 WITH BIOLINE COATING


  6. PERFUSION SET WITH BIOLINE COATING

Reason

In December 2014 Maquet Cardiopulmonary notified you via DYR 91 (FSN 2014-12-11) of the increased incidence of blood leakage from the gas outlet connector of the QUADROX-iD Adult and Small Adult products, including the HLS and PLS sets that contain related oxygenators of this product family.  The increased leakage was due to a separation of a small number of the internal fibers from the polyurethane casting in the oxygenator.  This separation resulted in the blood leakage that was the subject of the field safety notice. Since the release of this notification, we have been able to confirm the possible root cause that was described in the notification.  Additionally, we have implemented and validated the necessary corrections that return the products to their original performance specifications. The correction necessary was the implementation of additional process controls during the production process of these fibers at our raw material supplier. The fibers produced under these increased process controls have now been delivered to Maquet Cardiopulmonary and used on the production of the finished oxygenator products.