Health Products

Asena GH and Alaris Syringe Pumps (2017-05-04)

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: Healthcare Professionals, General Public, Hospitals
Department: Health Canada
Hazard classification: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberCompaniesBrand nameModel or catalog number
More than 10 numbers, contact manufacturer
Manufacturer
Carefusion Switzerland 317 Sarl
A-One Business Centre, Zone D'Activites, Vers-La-Piece No 10
Rolle
CH-1180
SWITZERLAND
F. Alaris Tiva Syringe Pump (Rebranding)80043UN01
More than 10 numbers, contact manufacturer
Manufacturer
Carefusion Switzerland 317 Sarl
A-One Business Centre, Zone D'Activites, Vers-La-Piece No 10
Rolle
CH-1180
SWITZERLAND
G. Alaris GH Syringe Pump (Rebranding)80023UN01
More than 10 numbers, contact manufacturer
Manufacturer
Carefusion Switzerland 317 Sarl
A-One Business Centre, Zone D'Activites, Vers-La-Piece No 10
Rolle
CH-1180
SWITZERLAND
D. Alaris CC Syringe Pump With Guardrails Safety Software (Rebranding)80033UND1-G
More than 10 numbers, contact manufacturer
Manufacturer
Carefusion Switzerland 317 Sarl
A-One Business Centre, Zone D'Activites, Vers-La-Piece No 10
Rolle
CH-1180
SWITZERLAND
E. Alaris Cc Syringe Pump (Rebranding)80033UND1
More than 10 numbers, contact manufacturer
Manufacturer
Carefusion Switzerland 317 Sarl
A-One Business Centre, Zone D'Activites, Vers-La-Piece No 10
Rolle
CH-1180
SWITZERLAND
B. Alaris PK Syringe Pump (Rebranding)80053UN01
More than 10 numbers, contact manufacturer
Manufacturer
Carefusion Switzerland 317 Sarl
A-One Business Centre, Zone D'Activites, Vers-La-Piece No 10
Rolle
CH-1180
SWITZERLAND
C. Alaris GH Syringe Pump With Guardrails Safety Software (Rebranding)8002MED01-G
More than 10 numbers, contact manufacturer
Manufacturer
Carefusion Switzerland 317 Sarl
A-One Business Centre, Zone D'Activites, Vers-La-Piece No 10
Rolle
CH-1180
SWITZERLAND
A. Asena GH80023FR01

Introduction

Affected Products

A. Asena GH
B. Alaris PK Syringe Pump (Rebranding)
C. Alaris GH Syringe Pump With Guardrails Safety Software (Rebranding)
D. Alaris CC Syringe Pump With Guardrails Safety Software (Rebranding)
E. Alaris CC Syringe Pump (Rebranding)
F. Alaris Tiva Syringe Pump (Rebranding)
G. Alaris GH Syringe Pump (Rebranding)

Reason

While the pump is infusing, a breakage of the plunger backplate spring may allow movement of the syringe plunger that may result in siphonage. Neonatal and paediatric patients, or those receiving critical drugs at low infusion rates, would be considered to be the most at risk if small volumes of fluids reach the patient due to siphoning.
Get told about the next health product recall.
Get health product recall alerts

CA$3.99/mo · cancel anytime