H. EVIS EXERA II Ulrrasonic Bronchofibervideoscope
BF-UC180F
All lots.
Manufacturer
Olympus Medical Systems Corp.
2951 Ishikawa-cho
Hachioji-shi, Tokyo
192-8507
JAPAN
I. Airway Mobilescope Therapeutic
MAF-TM
All lots.
Manufacturer
Olympus Medical Systems Corp.
2951 Ishikawa-cho
Hachioji-shi, Tokyo
192-8507
JAPAN
F. OES Bronchofiberscope
BF-1T40
All lots.
Manufacturer
Olympus Medical Systems Corp.
2951 Ishikawa-cho
Hachioji-shi, Tokyo
192-8507
JAPAN
G. EVIS EXERA Video System Bronchofibervideoscope
BF-MP160F
All lots.
Manufacturer
Olympus Medical Systems Corp.
2951 Ishikawa-cho
Hachioji-shi, Tokyo
192-8507
JAPAN
D. EVIS EXERA Video System Bronchovideoscope
BF-160
All lots.
Manufacturer
Olympus Medical Systems Corp.
2951 Ishikawa-cho
Hachioji-shi, Tokyo
192-8507
JAPAN
E. EVIS 240 Video System Bronchofibervideoscope
BF-1T240
All lots.
Manufacturer
Olympus Medical Systems Corp.
2951 Ishikawa-cho
Hachioji-shi, Tokyo
192-8507
JAPAN
B. EVIS EXERA II Video System Bronchofibervideoscope
BF-1T180
All lots.
Manufacturer
Olympus Medical Systems Corp.
2951 Ishikawa-cho
Hachioji-shi, Tokyo
192-8507
JAPAN
C. VISERA Video Rhino Laryngoscope
ENF-VT2
All lots.
Manufacturer
Olympus Medical Systems Corp.
2951 Ishikawa-cho
Hachioji-shi, Tokyo
192-8507
JAPAN
A. EVIS EXERA Ultrasonic Bronchofibervideoscope
BF-UC160F-OL8
Introduction
Affected products
A. EVIS EXERA Ultrasonic Bronchofibervideoscope
B. EVIS EXERA II Video System Bronchofibervideoscope
C. VISERA Video Rhino Laryngoscope
D. EVIS EXERA Video System Bronchovideoscope
E. EVIS 240 Video System Bronchofibervideoscope
F. OES Bronchofiberscope
G. EVIS EXERA Video System Bronchofibervideoscope
H. EVIS EXERA II Ulrrasonic Bronchofibervideoscope
I. Airway Mobilescope Therapeutic
Reason
Olympus received a complaint outside of Canada claiming that patients were infected after a bronchoscopy procedure in which a BF-1T180 bronchoscope with a loosened instrument channel port was used. As a result of Olympus’s investigation, it was discovered that the attachment of non-Olympus accessories to the bronchoscope's instrument channel port may have resulted in more applied force than expected and lead to loosening of the instrument channel port.
In an effort to maximize patient safety and mitigate any potential risk to patient health, Olympus is notifying users of this complaint and the need for careful inspection of the endoscope's instrument channel port prior to use in accordance with the instructions provided. Additionally, Olympus is providing updated Instruction For Uses (IFU).