YSIO Max, Luminos DRF, Uroskop Omni Max, Luminos Agile Max (2020-01-17)

· Published by Health Canada · Official notice

Details

Alert type: Medical Device Recall
Category: Medical Device
Issue: Medical Devices
Audience: General Public, Healthcare Professionals, Hospitals
Department: Health Canada
Hazard classification: Type II
Get told about the next health product recall.

We email or text you when Canada issues a recall that matches what you watch: a brand, a product, an allergen. Most never make the news.

Get health product recall alerts

CA$3.99/mo · cancel anytime

Products

Lot or serial numberCompaniesBrand nameModel or catalog number
Not applicable. 
Manufacturer
Siemens Healthcare GMBH
Henkestr. 127
Erlangen
91052
GERMANY
D. Luminos Agile Max10762472
Not applicable.
Manufacturer
Siemens Healthcare GMBH
Henkestr. 127
Erlangen
91052
GERMANY
B. Luminos DRF Max10762471
Not applicable.
Manufacturer
Siemens Healthcare GMBH
Henkestr. 127
Erlangen
91052
GERMANY
C. Uroskop Omni Max10762473
Not applicable.
Manufacturer
Siemens Healthcare GMBH
Henkestr. 127
Erlangen
91052
GERMANY
A. YSIO Max10762470

Introduction

Affected Products
  1. YSIO Max
  2. Luminos DRF Max
  3. Uroskop Omni Max
  4. Luminos Agile Max

Reason

Siemens is notifying users of two potentially hazardous issues and a software update intended to correct these issues. The potential hazards are two separate issues; however, they will be addressed with the same software update.

Issue # 1: Using the override function in case of blocked system movements affecting Luminos dRF Max, Luminos Agile Max and Uroskop Omnia Max systems. The potential exists for a system collision due to incorrect use of the bypass key overriding the built-in collision control. The bypass key is intended to enable movement of an otherwise blocked system to avert immediate hazard, e.g. to recover a patient following device error or in case of emergency. It is not intended for permanent use. During the use of the bypass key, the system regains movement using the ""override"" function, however, the user controls all system movements as the collision supervision functions are no longer active. There is a risk of collision with obstacles or persons when the operator uses the override function.

Issue # 2: Incorrectly assigned image affecting Ysio Max, Luminos dRF Max and Luminos Agile Max systems with detector MAX Static The potential exists for one image to be assigned to two different patients. In the unlikely event of an interrupted connection to a MAX Static detector during patient examination, a previously acquired image (possibly belonging to the previous patient) could be duplicated and stored in the current patient’s data set.